COMMERCIAL HEAT PUMPS

Commercial heating.
Engineered to scale.

HISA supplies R290 commercial air source heat pumps in 50 kW and 75 kW models for commercial, multi-residential and larger-building heating applications in the UK. Designed to operate individually or in cascade, with outlet water temperatures up to 75°C subject to operating conditions.

HISA 75 kW commercial R290 heat pump with two top-mounted fans
HR290-075C-3PH / 75 kW designation

DISCUSS YOUR PROJECT

Tell us a little about your project and a member of the HISA team will get in touch.

Online enquiries are not currently enabled. Please email or call HISA using the details on this page.

All fields are required.

HISA will use your details to respond to your enquiry. Read our Privacy Policy for more information. Submitting this enquiry does not sign you up for marketing.

50 / 75 kW

Two model designations.
Output depends on operating conditions.

Up to 75°C

Maximum outlet water.
Subject to operating conditions.

Up to 16

Units in parallel.
Project-specific design required.

R290

Refrigerant across both models.
GWP 3, as listed in the source.

01 / High temperature

Design around
the building’s duty.

High-temperature capability creates options for commercial heating projects. The right selection starts with heat loss, emitters, operating temperatures and the electrical supply—not the model number.

75°C is a maximum outlet-water temperature, not a guarantee at every ambient condition or at rated output. Suitability, emitters, heat demand and hydraulic/electrical design must be assessed for each project.

02 / Cascade

One unit.
A coordinated plant.

HISA commercial heat pumps support parallel operation of up to 16 units. Plan the arrangement around the building load profile, available space and project control strategy.

One unit

Individual heat pump

Multiple units

Coordinated operation

The building

Project heating demand

Functional concept only—not a hydraulic, electrical or installation schematic. Confirm plant sizing, sequencing, controls and hydraulic arrangements with the project team.

03 / Controls & BMS

MODBUS RS485.
Part of the wider system.

Bring building-management requirements into the design conversation from the start. Confirm the interface, equipment and configuration required for your project.

01

MODBUS RS485 communication

02

WiFi remote control

03

OTA connectivity

04

DTU connectivity

05

Power consumption monitoring

Features listed in the supplied source. Availability, accessories, network provision, integration scope and configuration must be confirmed with HISA. No live monitoring service is provided by this website.

04 / Applications

Commercial projects.
Considered individually.

From new developments to existing estates, suitability depends on the actual building and its operating requirements.

  • Housing and apartment developments
  • Hotels and hospitality
  • Offices
  • Schools and education estates
  • Healthcare premises
  • Leisure facilities
  • Retail
  • Factories and commercial premises
  • Restaurants
  • Transport facilities

Housing and apartment developments require a project-specific communal-heating assessment; the commercial range is not an automatic selection for every housing scheme.

05 / Technical library

Inspect the detail.

Choose a model designation. Review exact performance records, source-listed specifications and original drawings without assuming that one duty represents every condition.

Model designation

50 and 75 kW commercial models

Performance

The operating point matters.

Model designations are not guaranteed outputs. Review the operating level and temperatures together, then confirm project selection with HISA.

HR290-050C-3PH 50 kW designation

Numerical 50 kW performance points are withheld while HISA verifies differences between the catalogue and supplied tables. The original catalogue curves are shown for reference only; no selectable figures are estimated from them. Obtain confirmed project data before equipment selection.

Original catalogue heating-capacity and COP curves for the 50 kW commercial modelOpen original image at full size ↗
Original source curves · reference only. No selectable numerical 50 kW points.

HR290-075C-3PH 75 kW designation

Each selectable value is an exact supplied capacity/COP pair at the same operating level, ambient temperature and water outlet temperature. Lines join measured points for readability, not interpolation. The structured data does not specify wet-bulb or water-inlet conditions; do not treat the full curves as the catalogue A7/6 test condition.

All 72 supplied 75 kW capacity / COP pairs
HR290-075C-3PH · Exact supplied pairs. Operating level, ambient and water outlet are specified for every row. Wet-bulb and water-inlet conditions are not specified.
ModelOperating levelAmbient °CWater outlet °CCapacity kWCOPOther test conditions
HR290-075C-3PHMAX-253557.0542.1484596273292Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-203561.5642.40777639751553Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-123567.45122.72695575427117Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-103568.9232.81014161490683Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX03576.8893.332Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX73588.784.13Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX103592.394.432Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX2035105.2225.369Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX3035117.96.432Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-255558.3441.616Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-205562.8791.804Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-125568.86622.04094795492773Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-105570.3632.10264782608696Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX05578.4192.485Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX75590.423.08Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX105594.1383.306Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX2055107.263.998Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX3055119.994.773Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX-107571.751.37802360248447Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX07579.9021.629Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX77592.062.017Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX107595.872.16Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX2075109.42.617Wet-bulb / water inlet: not specified
HR290-075C-3PHMAX3075122.033.127Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-253548.56466298715932.24209709292708Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-203552.40359855823382.51271580467117Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-123557.41481396710972.84580612612803Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-103558.66761781932872.93261752064127Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED03565.44831865284973.47722033898305Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED73575.574.31Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED103578.64285086731244.62516222760291Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED203589.56551633250735.603Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED3035100.3570961928366.71232929782082Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-255548.85745401459851.63961038961039Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-205552.65507765980981.83035714285714Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-125557.6687782747182.07076699972375Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-105558.9222034284452.13336833003953Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED05565.66832384428222.52130681818182Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED75575.7183.125Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED105578.83146520681273.35430194805195Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED205589.81987038265874.05641233766234Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED3055100.480013492594.84273538961039Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED-107559.12867151857491.4552257180426Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED07565.84667751466441.72026276648488Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED77575.8662.13Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED107579.00579426461012.28101140307387Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED207590.15577232239852.76361427863163Wet-bulb / water inlet: not specified
HR290-075C-3PHRATED3075100.5640666956333.30218641546852Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-253512.84004190132912.84553853789122Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-203513.85502050011263.18899198411863Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-123515.17993890515883.61173074476109Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-103515.51116850642043.72190669092987Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN03517.30392227979274.41308474576271Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN73519.985.47Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN103520.7924329804015.86998547215496Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN203523.68028339716157.111Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN303526.53347600810998.51889588377724Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-255512.53086131386861.80540779220779Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-205513.50486817075872.01544285714286Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-125514.79077199734572.28016295873582Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-105515.11224795399252.34909453557313Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN05516.84247931873482.77626136363636Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN75519.423.441Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN105520.21853527980543.69348896103896Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN205523.03681928776824.46659675324675Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN305525.77091130280915.33243279220779Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN-107514.69916358896371.73875561146404Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN07516.36923441233982.05543133366386Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN77518.862.545Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN107519.64054095155332.72543381259296Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN207522.41238322832943.30206494794249Wet-bulb / water inlet: not specified
HR290-075C-3PHMIN307524.99984575276993.9455701536936Wet-bulb / water inlet: not specified

Specification

Source-listed technical data.

Ranges below retain their catalogue standard conditions. These are distinct from the structured performance records above. Confirm project-specific duties before selection.

HR290-050C-3PH 50 kW designation

Model
HR290-050C-3PH
Product name
HISA R290 50 kW Commercial Heat Pump
Model designation (not test-point output)
50 kW
Power supply
380–415 V / 3 phase / 50 Hz
Refrigerant
R290
GWP (source-listed)
3
Fan motor
DC inverter
Compressor
DC inverter
Ingress protection
IPX4
Sound pressure at 1 m
65 dB(A)
Maximum outlet-water temperature
75°C — subject to operating conditions
Water pressure (source-listed)
0.1 / 0.3 MPa
Heating ambient range
−25 to 45°C
Cooling ambient range
16 to 45°C
ErP at 35°C
A++
Maximum input power
19.84 kW
Maximum input current
30.3 A
Rated water flow
8.6 m³/h
Number of fans
1
Water connection
DN40 (G 1-1/2")
Maximum water pressure drop
65 kPa
Dimensions · L × W × H
1155 × 990 × 1880 mm
Net weight
500 kg
Heating · 35°C water outlet

Catalogue standard condition: A7/6°C · W30/35°C

Capacity range
17.56–50 kW
Input power range
2.61–12.88 kW
Input current range
5.46–18.8 A
Heating · 55°C water outlet

Catalogue standard condition: A7/6°C · W47/55°C

Capacity range
17.95–49 kW
Input power range
3.48–17.2 kW
Input current range
7.78–26.8 A
Cooling

Catalogue standard condition: A35/24°C · W12/7°C

Capacity range
10–35 kW
Input power range
3.84–14.50 kW
Input current range
6.42–20.56 A

75°C is a maximum outlet-water temperature, not a guarantee at every ambient condition or at rated output. Suitability, emitters, heat demand and hydraulic/electrical design must be assessed for each project.

HR290-075C-3PH 75 kW designation

Model
HR290-075C-3PH
Product name
HISA R290 75 kW Commercial Heat Pump
Model designation (not test-point output)
75 kW
Power supply
380–415 V / 3 phase / 50 Hz
Refrigerant
R290
GWP (source-listed)
3
Fan motor
DC inverter
Compressor
DC inverter
Ingress protection
IPX4
Sound pressure at 1 m
65 dB(A)
Maximum outlet-water temperature
75°C — subject to operating conditions
Water pressure (source-listed)
0.1 / 0.3 MPa
Heating ambient range
−25 to 45°C
Cooling ambient range
16 to 45°C
ErP at 35°C
A+++
Maximum input power
45.84 kW
Maximum input current
70.6 A
Rated water flow
12.9 m³/h
Number of fans
2
Water connection
DN65
Maximum water pressure drop
23 kPa
Dimensions · L × W × H
2200 × 1100 × 2190 mm
Net weight
770 kg
Heating · 35°C water outlet

Catalogue standard condition: A7/6°C · W30/35°C

Capacity range
19.98–88.78 kW
Input power range
3.65–21.49 kW
Input current range
Withheld — pending HISA engineering verification
Heating · 55°C water outlet

Catalogue standard condition: A7/6°C · W47/55°C

Capacity range
19.42–90.42 kW
Input power range
5.64–29.35 kW
Input current range
Withheld — pending HISA engineering verification
Cooling

Catalogue standard condition: A35/24°C · W12/7°C

Capacity range
10.85–62.75 kW
Input power range
3.04–21.98 kW
Input current range
Withheld — pending HISA engineering verification

Condition-specific current-input figures for the 75 kW model are withheld pending HISA engineering verification. The separately listed maximum input current is retained.

75°C is a maximum outlet-water temperature, not a guarantee at every ambient condition or at rated output. Suitability, emitters, heat demand and hydraulic/electrical design must be assessed for each project.

Dimensions

Plan with the original drawings.

Original cropped source drawings, not redrawn diagrams. Open at full size to read annotations. Confirm installation dimensions and service clearances during project design.

HR290-050C-3PH 50 kW designation

Original dimension drawing for HR290-050C-3PHOpen original image at full size ↗
HR290-050C-3PH · original source drawing
Length
1155 mm
Width
990 mm
Height
1880 mm
Net weight
500 kg

The specification table lists 1155 × 990 × 1880 mm. The supplied plan drawing labels one overall dimension 987 mm rather than 990 mm. Both are retained without correction; confirm dimensional details before installation.

Downloads

Take the detail into your project.

HISA Commercial R290 Heat PumpsCommercial range · 50 and 75 kW designationsPDF ↓

Read alongside the performance, current-input and dimensional verification notices on this page. Request confirmed project data before equipment selection.

06 / Project support

Bring HISA in early.

Start with the building, not the product. Share the project stage, estimated heat demand, required flow temperature and any constraints so we can discuss the next steps with your design team.

Support the design conversation.

Talk through equipment selection, cascade concepts, controls integration and the information needed for your specification. Final suitability and system design remain project-specific.

Commercial and non-domestic applications may be subject to separate warranty arrangements agreed by HISA.